Electrical Component Quiz
Ten questions on contactors, capacitors, compressors, transformers and motors. Pick an answer to see whether you are right and why. Related reading: The Code: controls.
-
A contactor in an outdoor unit is:
- A switch with a low-voltage coil that opens and closes the line-voltage circuit to the compressor and fan
- A device that stores electrical charge
- A refrigerant pressure sensor
- A transformer
The 24-volt coil pulls in contacts that carry line voltage to the loads. That is how a thermostat's small signal controls large loads.
-
The run capacitor on a PSC motor:
- Only helps it start
- Stays in the circuit while it runs, creating the phase shift that helps the motor run efficiently
- Converts AC to DC
- Limits current to the motor
A run capacitor feeds the start winding for the whole run cycle. A weak one can make a motor run hot, draw more current or fail to start.
-
On a single-phase compressor, the three terminals are:
- Line 1, Line 2 and Ground
- Common, Start and Run
- Hot, Neutral and Ground
- R, C and G
C, S and R connect to the start and run windings inside the compressor.
-
Between which two compressor terminals is the resistance highest?
- Common to Run
- Common to Start
- Start to Run
- Each terminal to ground
Start to Run goes through both windings in series, so it reads the sum of the other two readings.
-
You measure continuity from a compressor terminal to the compressor's copper or shell. This means:
- Normal operation
- A grounded winding, and the compressor should not be energized
- A bad capacitor
- A welded contactor
The windings should be insulated from the shell. A ground fault is dangerous and usually means the compressor has failed.
-
A transformer rated 40 VA with a 24-volt secondary can supply about:
- 0.6 amps
- 1.7 amps
- 10 amps
- 40 amps
Volt-amps divided by volts gives amps: 40 ÷ 24 is about 1.7 amps. Overload it and it overheats.
-
A hard start kit is used to:
- Make a compressor run faster
- Give a compressor extra starting torque with a start capacitor that drops out once it is running
- Replace the contactor
- Lower head pressure
The start capacitor boosts starting torque and is then taken out of the circuit. It can help a compressor that struggles to start, but it does not fix a mechanical failure.
-
An ECM blower motor differs from a PSC motor because it:
- Has no electronics
- Uses an electronic control module to vary its speed and is typically more efficient
- Needs a run capacitor
- Runs at only one speed
ECMs are brushless DC motors with a built-in control. They can hold airflow or torque across conditions and use less power than PSC motors.
-
Pitted, burned contactor contacts can cause:
- Higher refrigerant pressure only
- Voltage drop across the contacts, overheating and hard starting
- Lower indoor airflow
- A short in the thermostat
Damaged contacts add resistance, which drops voltage to the compressor and heats the contacts. Measure voltage across the closed contacts under load to find it.
-
A dual run capacitor has terminals marked C, FAN and HERM. HERM connects to:
- The condenser fan motor
- The compressor
- The thermostat
- Ground
HERM refers to the hermetic compressor. FAN goes to the condenser fan motor, and C is common to both.