Thermostat Function Quiz
Ten questions on thermostat terminals and what each one controls. Pick an answer to see whether you are right and why. Related reading: The Code: controls.
-
The R terminal on a thermostat is:
- The reversing valve
- The 24-volt power from the transformer
- The return air sensor
- The common
R is the hot side of the 24-volt control transformer. The thermostat switches R to the other terminals to make a call.
-
Which terminal turns on the indoor blower?
- W
- Y
- G
- C
G energizes the indoor fan relay or tells the furnace or air handler board to run the blower.
-
A call for cooling energizes which terminal?
- Y
- W
- O/B
- E
Y energizes the compressor contactor in the outdoor unit. The indoor blower runs too, through G or through the equipment's own control.
-
The C terminal provides:
- Cooling
- A common return path to the transformer, so the thermostat has continuous power
- A connection to the compressor
- Constant fan
C completes the 24-volt circuit back to the transformer. Smart and Wi-Fi thermostats usually need it for steady power.
-
On a heat pump, the O terminal typically energizes the reversing valve in:
- Heating
- Cooling
- Defrost only
- Emergency heat
With O, the reversing valve is energized in cooling. Some manufacturers use B, which energizes it in heating. Set the thermostat to match the equipment.
-
W on a furnace thermostat calls for:
- Heat
- Cooling
- Fan only
- A humidifier
W starts the heating sequence on a furnace, or auxiliary heat on some heat pump setups.
-
Emergency heat on a heat pump thermostat:
- Runs the compressor at full speed
- Locks out the compressor and heats with the backup heat source
- Turns off all heat
- Starts a defrost cycle
Emergency heat is for when the heat pump is out of service. It heats with electric strips or a furnace only, which usually costs more to run.
-
Y2 or W2 on a thermostat is used for:
- A second thermostat
- A second stage of cooling or heating
- A second transformer
- A Wi-Fi module
Two-stage equipment uses Y1 and Y2 for cooling stages and W1 and W2 for heating stages. The second stage runs when the first cannot keep up.
-
A thermostat is best mounted:
- On an outside wall in direct sun
- On an inside wall away from drafts, supply registers and heat sources
- Above the kitchen stove
- Inside the return duct
The thermostat should sense the temperature of the space. Sun, drafts, appliances and supply air make it read wrong and cycle the system badly.
-
Wire colors at the thermostat:
- Are fixed by code and always correct
- Are a convention; the terminal letter is what matters
- Determine the voltage
- Must match the colors in the outdoor unit
Installers often use red for R, white for W, green for G and yellow for Y, but nothing guarantees it. Label wires by terminal before you disconnect them.