Multimeter Basic Function Quiz
Ten questions on using a multimeter safely and reading it correctly. Pick an answer to see whether you are right and why. Related reading: The Code: controls.
-
To measure voltage, the meter leads are connected:
- In series with the load
- In parallel, across the two points being measured
- To ground only
- With the circuit de-energized
Voltage is a difference in potential between two points, so the meter goes across them, with the circuit energized.
-
The safest common way to measure current on an HVAC circuit is to:
- Put the meter leads in series with the motor
- Clamp a clamp meter around a single conductor
- Clamp around both conductors of a circuit at once
- Measure resistance and divide
A clamp meter senses the magnetic field around one conductor without breaking the circuit. Clamping both conductors cancels the fields and reads near zero.
-
Before measuring resistance, you must:
- Energize the circuit
- Turn off the power and isolate the component
- Set the meter to AC volts
- Ground both leads
An ohmmeter supplies its own small current. Measuring a live circuit can damage the meter and gives a false reading, and parallel paths in the circuit skew it too.
-
A meter reading OL on the ohms setting across a switch usually means:
- The switch is closed
- The path is open, with resistance beyond the meter's range
- The meter battery is dead
- The switch is shorted to ground
OL means over limit: the resistance is too high to measure, which on a switch or a winding means an open.
-
Before testing a run capacitor's microfarads, you should:
- Leave it connected and energized
- Safely discharge it and disconnect at least one lead
- Warm it up
- Measure it on AC volts
Capacitors can hold a dangerous charge after the power is off. Discharge it safely, then measure capacitance with the leads disconnected.
-
A run capacitor rated 45 µF ±6% measures 40 µF. It is:
- Within tolerance
- Below tolerance and should be replaced
- Above tolerance
- Fine, as long as it is not bulging
Six percent of 45 is 2.7, so the acceptable range is about 42.3 to 47.7 µF. A reading of 40 µF is below it.
-
A continuity test checks whether:
- Voltage is present
- There is a complete, low-resistance path between two points
- A motor is drawing the right current
- A capacitor is charged
Continuity mode beeps when resistance is very low, confirming an unbroken path. It is an ohms test, so the circuit must be de-energized.
-
What does the CAT rating on a meter, such as CAT III, describe?
- The meter's accuracy
- The level of voltage spikes the meter is built to withstand where it is used
- The battery type
- The maximum current it can read
Measurement categories rate a meter and its leads for the transient overvoltages found at different points in an electrical system. Use a meter rated for where you are working.
-
You read almost 0 volts across the contacts of a closed contactor that is carrying load current. This means:
- The contacts are open
- The contacts are making good contact
- There is no power to the unit
- The coil is shorted
Good closed contacts have very little voltage drop across them. A noticeable voltage across closed contacts under load points to pitted or burned contacts.
-
Which meter setting is used to check a residential 24-volt control circuit?
- DC millivolts
- AC volts
- Ohms
- Microamps
The control transformer supplies about 24 volts AC, and it often reads a few volts higher when lightly loaded.